  hand-held communicator < hhc > display unit: lcd, 16 digits 4 lines operating unit: flat keys (32 keys), power switch, set value protection key switch power source: built-in nickel-cadmium battery battery life: 24 hours (without option under standard conditions after full charge) charger power source: 100, 115, 230v 10% ac, 50/60hz (as specifed) charging time: 5 hours printer (option): printing of 24 digits of each remote item ambient temperature: -10 to +50c storage temperature: -20 to +60c ambient humidity: 90% rh or less hazardous locations: designed to meet international intrinsic safety standards. applications have been submitted for the following. (in case of without printer only) emc comformity: en61326 functional specifcations remote function: see the next page. power alarm function: battery voltage drop is detected and indicated by lamp fickering on display unit (batt alm). set value protective function: set value can be changed by using key switch automatic power standby function: hhc automatically enters into standby mode when key is not accessed for more than 10 minutes (data measure - ment only). features specifications fxw this instrument is a handy type communicator with built- in battery, being designed to perform facilitated commu - nication with operater through use of "smart" type fcx series transmitter. 1. simple operation adoption of large lcd display (16 digits 4 lines) as well as menu assisted software design provides easy-to- use communication interface. 2. application to every type of device the communicator can be used with any "smart" type of fcx transmitter, fcx-a/c transmitter, fcx-ax transmit - ter and fcx-aii/cii, aiii transmitter. 3. on-line operation the communicator can be operated without interrupting 4 to 20ma dc signal. 4. full variety of protective functions the communicator incorporates transmitter diagnostic function, data-write protection key, battery voltage drop alarm function, automatic power standby function, etc. 5. optional printer set data can be printed on an optional printer. standard specifcations applicable device: "smart" type fcx series transmitter fcx transmitter fcx-a/c transmitter fcx-ax transmitter fcx-aii/cii transmitter fcx-aiii transmitter transmission line requirement: line length; max 2km (0.75 to 1.25mm 2 cable. for 1km and above, twist pair- cable is recommended.) load resistance; 250 to 578 ? in case of fcx-1 trans - mitter 250 to 600 ? in case of fcx-a/c, fcx-ax, fcx-aii/cii transmitter (including cable resistance at 24v dc in case of fcx-aiii transmitter; refer to load limitations. load capacitance; 0.22f max. load inductance; 3.3mh max. separation from power line; 15cm or more (avoid parallel wiring.) authorities atex eex ia iic t3 date EDS8-47N apr. 1, 2011 data sheet
fxw 2 physical specifcations material: polycarbonate color: gray dimensions (h x w x d): 55 x 98 x 223mm (without printer) mass: approx. 500g (without printer) remote functions items display set tag no. v v model no. v v serial no. & software version v engineering unit v v range limit v measuring range v v damping v v output mode v burnout direction v v calibration v v output adjust v data v self diagnoses v printer (in case of fxw with printer option) v external switch lock v v transmitter display v v linearize v v rerange v v saturate current v v write protect v v history C calibration history C ambient temperature history v v v note: hhcs version must be higher than 7.1 (or fxw 1? 4), for fcxCa iii . load limitations 2000 r [?] 1500 1000 load resistance 500 250 0 1474 ? 577 ? operating area 24v 45v communicable range with hand-held communicator 10 16.35 50 e [v] 10.5v power supplay voltage e (dc) when imax is 22.5ma r= e-10.5 (imax+0.9)x10 -3 note: imax is the bigger one, either upper saturation current [ma] or upper burnout current [ma]. when imax is from 20ma to 21.6ma, calculate load resistance using imax of 21.6ma. and when imax is from 21.7ma to 22.5ma, calculate load resistance using the formula in the fgure. igd1dayt(g6a remarks the fcx-aii/cii, aiii series cannot be operated with the hhc whose software is older than version 6.0. the ver - sion of the hhc software can be upgraded by exchang - ing the built-in rom. contact the nearest fuji electric representative when it needs to be upgraded. (the software version can be checked on the screen dis - play which appears when turning on hhc power supply.) w 1 a 4 - x f description 1 2 3 4 5 6 7 8 9 10 printer without with (explosion-proof structure is not applicable) 1 2 charger without 100v ac 50/60hz 115v ac 50/60hz 230v ac 50/60hz 0 1 2 3 application general a use fcx, fcx-a/c, fcx-ax, fcx-aii/cii, fcx-aiii transmitter (hhc software version 7.1 or upper) 4 carrying case without with y a explosion-proof structure for hazardous locations without intrinsic safety explosion-proof (atex) a k
3 outline diagram (unit:mm) printer (option) 98 66 127 ?8 8 215 8 89 (55) (53) 2 (350) 42 power supply transmission signal connector key switch battery charger connector connection (for example fcx-aiii transmitter) dc power source for the power supply voltage, refer to the specification "operation area between power supply voltage and load resistance" of each field equipments. load resistor 250? or more instrument room terminal blok junctoin terminal field device hhc hhc hhc to junction terminal or instrument room hhc (connect to transmitter "+" and "C" terminals)
hhc, special cable (with clips), keys (2) charger, carrying case, printer (based on code symbols) scope of delivery option fxw the product conforms to the requirements of the electromagnetic compatibility directive 2004/108/ec. the applicable standards used to demonstrate compliance are :- frequency range mhz limits reference standard 30 to 230 40db (v/m) quasi peak, measured at 10m distance 230 to 1000 47db (v/m) quasi peak, measured at 10m distance en55011 phenomenon test value basic standard performance criteria b electrostatic discharge electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz : 10v/m 1.4 to 2.0ghz : 3v/m 2.0 to 2.7ghz : 1v/m 80%am (1khz) en61000-4-2 a en61000-4-3 rated power frequency magnetic field 30a/m 50hz a en61000-4-8 emi (emission) en61326-1 : 2006 group 1 class 1 ems (immunity) en61326-1: 2006 table 2 (for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering. printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDS8-47N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X